HPGS-V16HW

SPLIT R32 DC INVERTER · Air-to-Water Heat Pump

HPGS-V16HW

Cooling: 15.2 kW
Heating: 16.0 kW

The HPGS-V16HW is the absolute flagship of SENSEI’s split-type air-to-water heat pump lineup, delivering a powerful nominal thermal capacity of 16.0 kW heating and 15.2 kW cooling (configured for a stable three-phase 380V electrical supply). The system pairs a heavy-duty outdoor unit with an indoor hydro-module. We recommend this ultimate setup for spacious private estates, modern multi-level villas, and light commercial properties ranging from 140 to 180 m². It is the ideal choice for driving extensive underfloor heating networks, low-temperature radiators, and active fan-coil cooling systems while prioritizing high-volume domestic hot water (DHW) production.



Official warranty
Delivery across Ukraine

Year-Round Comfort

This premier split system acts as a high-capacity climate engine certified for stable heating in extreme winter conditions down to -28°C, and highly effective cooling in summer up to +43°C. Operating on a fully reversible cycle, it delivers chilled water for active cooling during the summer months. Driven by advanced inverter technology, it controls the flow temperature with a precision of ±0.5°C, eliminating drafts and ensuring outstanding thermal stability throughout the building.

Technical Advantages & Features

  • Top-Tier Seasonal Efficiency (A+++ Heating / A++ Cooling): Delivers 16.0 kW heating and 15.2 kW cooling capacity. Maximizes heat transfer from ambient outdoor air, drastically lowering seasonal heating bills for large properties.

  • Freeze-Safe Split Design: All water-carrying hydraulic connections, heat exchangers, and pumps are safely housed inside the indoor hydro-module. This completely eliminates any risk of external pipe bursts or freezing during unexpected winter power grid outages.

  • Heavy-Duty Twin-Rotary Compressor: Features a premium dual-stage inverter compressor with enhanced acoustic insulation, offering low-vibration performance with an outdoor sound power level of 70 dB.

  • Eco-Friendly R32 Refrigerant: Fully optimized to run on next-generation R32 refrigerant, which increases thermodynamic heat transfer efficiency while using a lower charge volume.

  • Color Touchscreen Controller: Equipped with an intuitive wired touch controller to easily program complex weather-dependent heating curves, DHW disinfection modes (Anti-Legionella), and active zone scheduling.

Best Suited For:

Owners of spacious private houses, villas, and cottages (140–180 m²) with a 3-phase (380V / 50Hz) electrical connection, who want to replace traditional gas, solid fuel, or electric boilers with a single, high-efficiency green energy system.

Might Not Be Suited For:

If your home's total heated area is under 110 m² or lacks a 3-phase grid connection, this 16.0 kW system is oversized and will cycle too frequently; in this scenario, the single-phase HPGS-V12HW is a much better, more economical choice.

PACKAGE CONTENTS

  • Indoor unit
  • Outdoor unit
  • Remote control
  • Installation manual
  • Warranty card

Got an error? Check its meaning here.

High pressure-ratio compressor

High pressure-ratio compressor — up to 13 — with better performance at low ambient temperatures. Renowned GMCC brand. DC rotary inverter compressor. Refrigerant: R32.

DC fan motor

Brushless DC fan motor. Higher efficiency, low noise level

Larger heat exchanger

A larger heat exchanger to match the required heat-exchange area at low ambient temperatures. Flat-type fins improve defrosting efficiency.

Integrated PCB

The integrated PCB for the single-phase unit reduces the risk of damage to each component.

Plate heat exchanger

Efficient heat transfer for both heating and cooling. Compact footprint. Withstands high temperatures and high pressure.

Inverter water pump

High-efficiency inverter water pump. Brand: Wilo Para series. Water head is 9 m for the 8 kW, 12 kW, and 16 kW hydronic modules. CE and VDE compliant, 50/60 Hz.

Expansion tank

When water heats up, it expands and its pressure rises. Without room for thermal expansion, serious problems can occur in the water system, including failure or rupture. The expansion tank maintains stable pressure in the water system. Pre-charge pressure: 0.15 MPa. Volume: 2 L.

KEY SPECIFICATIONS

Cooling (kW)
15.2
Heating (kW)
16.0
Compressor Type
Rotary DC inverter
Power Supply
380~415/3/50 V/Ph/Hz
Capacity (kW)
16
Poles
6
Speed (rps)
12~120
Oil
POE/1400mL
Motor Type
Brushless DC motor
Number of Fans
2
Heat Exchanger Rows
2
Compressor model
EKTQ420D1UMU
Charge Volume (kg)
3,8
Tube Pitch × Row Pitch (mm)
25x21,7
Heat Exchanger Tube Type and Diameter
Ф9.52 grooved copper pipe
Fin Spacing (mm)
1,6
Heat Exchanger Fin Type
Hydrophilic aluminum
Heat Exchanger Dimensions
995x1350x43,3
Number of Turns
7
Pipe Diameter (OD, mm)
Ф9.52
Expansion Device
EXV
Compressor Manufacturer
GMCC
Safety Valve (kPa)
600
Expansion Tank (volume, L)
2
Pump Head (m)
9
Number of Phases
1
Max. water pressure (kPa)
800 kPa
Nominal pressure (kPa)
150 kPa
Rated power consumption (kW)
3kW
Rated current (A)
13,6A
refrigerant_topup
(Total pipeline length is -5)m*30 g/m

PERFORMANCE

Air Flow (m³/h)
6100 m3/godz
EER Energy Efficiency
2,81 kW/kW
COP Energy Efficiency
3,4
Maximum Current Draw (A)
12,1
Energy Efficiency Class (water 35°C)
А++
Energy Efficiency Class (water 55°C)
А++
Max. Power Consumption (kW)
6,4
Max. power consumption, indoor (kW)
3,6 kW
Max. current, indoor (A)
17 A
SCOP Energy Efficiency
4,27 kW/kW
Power Consumption (kW)
3,75
Hot Water Temperature
40~60°C
Hot water supply, indoor (°C)
40~60°C

SOUND AND CONVENIENCE

Indoor Unit Noise Level (dB)
45
Outdoor Unit Noise Level (dB)
70

INSTALLATION AND PIPING

Maximum Line Length (m)
50 m
Operating Temperatures (Heating)
-28~43°C
Operating Temperatures (Cooling)
-5~46°C
Liquid Pipe Diameter (mm)
Ф9.52
Gas Pipe Diameter (mm)
Ф15.88
Height Difference (above, m)
20
Height Difference (below, m)
20
Connecting Pipe Diameter (outlet)
DN32
Connecting Pipe Diameter (inlet)
DN32
Cooling water temp, indoor (°C)
5~25 °C
Cooling water temp, outdoor (°C)
5~25°C
Heating water temp, outdoor (°C)
25~60°C
Heating water temp, indoor (°C)
25~60°C

INDOOR UNIT DIMENSIONS AND WEIGHT

Indoor Unit Weight (kg)
48/56 kg
Packing W×H×D, indoor (mm)
620*1105*425 mm
Indoor Unit Dimensions (W×D×H)
490*910*340 mm

OUTDOOR UNIT DIMENSIONS AND WEIGHT

Outdoor Unit Dimensions (W×D×H)
1014x1430x450 mm

OTHER SERIES